Energy Efficient Passive
Solar Home
1800 Ft2 4
BEDROOM
OPTIMIZE AS A SYSTEM
The following outline details the major design goals and the
related issues and elements.
Safety
-
Codes followed. Exceptions to codes that were allowed
by the building department (eg; no poly ground cover in pressurized and
heated crawlspace) were carefully reviewed.
Durability
-
Moisture control measures.
-
Vented rain screen.
-
Protected walls from exterior moisture sources.
-
Prolonged siding life.
-
Tight Envelope
-
Prevented air transported moisture into walls and attic.
-
Unvented attic:
-
Enabled by tight envelope and vapor diffusion retarder. Reduces moisture
loading in winter.
-
Vapor diffusion retarder.
-
Used latex paint rated at less than 1 perm by both wet and dry cup test
methods.
-
Depressurized occupied zone by continuous ventilation system.
-
Provided constant drying of walls in this climate.
-
Pressurized "crawlspace" zone with continuous ventilation system.
-
Carefully installed air & vapor retarders protected structural wood.
-
Conducted moisture monitoring to verify moisture control.
-
Ease of maintenance.
-
Very accessible filters
-
In HPVAC-80 Heat Pump Heat Recovery Ventilator.
-
In Earth Tube Intake Filter Box.
-
Separate mechanical room in conditioned space for maintenance access.
-
Pressure-difference manometers, fan speed controls
Comfort
-
Warm floors.
-
Zonal temperature control (heating season only).
-
High R glazing.
-
Tight envelope.
-
Acoustically quiet because of tight envelope, R45 walls, triple glazing,
etc.
-
Conditioned fresh air continuously ducted to most rooms.
-
Acoustically isolated bedroom and bathrooms.
Desired
Esthetics
-
Sense of volume, space, connection to outdoors.
-
Elevated ceiling and balcony hallway over living room.
-
Large windows.
-
Standard tempered patio door glazing: inexpensive, replaceable.
-
Ganged together & butt glazed to avoid visual obstruction.
-
Clean, simple, uncluttered interior: sheetrock and natural wood finishes.
-
Deep window sills with sheetrock wrap into window recesses.
-
Excellent light diffusion: "halo" effect.
-
Sills provide very handy shelves for artwork & other artifacts.
-
Preference for "real" wood reveal rather than more costly "cosmetic"
wood.
-
Structural glu-lambs left exposed.
-
Glu-lambs sealed with clear finish to enhance natural beauty (rather than
"wrapped in oak").
-
Recycled vertical grain fir cabinets less expensive and more esthetically
pleasing.
-
Wrap-around porch.
-
No solar penalty since tall spruce trees to south already obscured glazing.
-
Covered porch at main floor level for easy access and daily use.
Indoor
Air Quality
-
Make-up air via earth tubes filtered to remove most pollens and wood smoke
particles.
-
Make-up via depressurized envelope filtered by insulation (dynamic wall).
-
Continuous ventilation capable of adjustment over range of air change rates.
-
Owner can adjust particulate removal rate.
-
Radon.
-
Tight envelope enables mechanically induced pressure-difference control.
-
Climate impact on air change is negligible.
-
Continuous mechanical ventilation creates required pressure-differences.
-
Normal operation of continuous mechanical ventilation system has been adequate.
-
"Crawlspace" is really a pressurized exhaust air plenum.
-
Plenum has no vents and has airtight separation with respect to occupied
zone and outside.
-
Plenum is pressurized to prevent soil gas entry.
-
Air in plenum is continuously flushed to outside.
-
Formaldehyde.
-
All structural paneling has phenolic resins.
-
Linoleum underlayment is low emitting: HUD rated material.
-
Cabinets are mostly fir rather than particleboard.
-
No combustion appliances.
-
No lead-based paints.
-
Tight envelope isolates garage, solvents, cleansers etc.
-
Continuous ventilation capable of adjustment over range of air change
rates.
-
Owners can respond to occupant loads and other occasional pollutant loads.
-
Owners can respond to seasonal and other changes in pressure-differences
by adjusting fan speed controls.
Energy
Efficiency
-
Maximized available on-site solar potentials.
-
Addressed conduction with High R values.
-
Addressed convection with tight envelope.
-
Heat pump heat recovery ventilation provided 50% annual heat load.
-
Zonal electric resistance provided other 50% & allowed zonal "comfort/efficiency
tuning."
Cost
-
Owners' esthetic taste desired simplicity and function, and disliked
extravagance.
-
Owner's provided significant labor.
-
The building's estimated cost is between $45 and $50 per square
foot.